Description of the motor
2.3 Technical features and ambient conditions
1FW6 High Speed built-in torque motors
38
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
2.3.4
Defining the direction of rotation
Direction of rotation
If the built-in torque motor is connected with a phase sequence U-V-W, and is fed from a
three-phase system with a clockwise phase sequence, then the rotor rotates clockwise. You
can identify the direction of rotation by viewing the DE of the built-in torque motor. The cable
outlet of the built-in torque motor is on the opposite side – the NDE. Whether the rotor is
mounted on the DE flange or NDE flange has no effect on the direction of rotation of the
rotor.
①
NDE flange with cable outlet
②
Clockwise: The rotor turns clockwise (phase sequence U V W)
③
When viewing the DE flange
④
DE flange
Figure 2-4
Line of sight for determining the direction of rotation
2.3.5
Environmental conditions for stationary use
You can classify the ambient conditions for stationary use at weatherprotected locations
according to the standard IEC 60721-3-3. The environmental effects and their limit values
are defined in various classes in this standard.
Содержание 1FW6092-2PC15-6AB3
Страница 1: ...1FW6 High Speed built in torque motors ...
Страница 2: ......
Страница 10: ...Introduction 1FW6 High Speed built in torque motors 8 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 140: ...Configuration 5 4 Mounting 1FW6 High Speed built in torque motors 138 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 298: ...Index 1FW6 High Speed built in torque motors 296 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 299: ......
Страница 300: ......