Preparation for use
7.2 Storage
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
237
7.2
Storage
7.2.1
Ambient conditions for long-term storage
Based on EN 60721-3-1 (for long-term storage)
Table 7- 6
Climatic ambient conditions
Lower air temperature limit:
- 5 °C (deviates from 3K3)
Upper air temperature limit:
+ 40 °C
Lower relative humidity limit:
5%
Upper relative humidity limit:
85%
Rate of temperature fluctuations:
Max. 0.5 K/min
Condensation:
Not permissible
Formation of ice:
Not permissible
Long-term storage:
Class 1K3 and class 1Z1 have a different upper relative humidity
Storage is only permissible in locations that are fully protected against the weather (in halls or rooms).
Table 7- 7
Biological ambient conditions
Long-term storage:
Class 1B1
Table 7- 8
Chemical ambient conditions
Long-term storage:
Class 1C1
Table 7- 9
Mechanically active ambient conditions
Long-term storage:
Class 1S2
Table 7- 10 Mechanical ambient conditions
Long-term storage:
Class 1M2