Configuration
5.2 Configuring workflow
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
91
5.2.2
Type of load cycle
Uninterrupted duty S1
With uninterrupted duty S1, the motor runs permanently with a constant load. The load
period is sufficient to achieve thermal equilibrium.
The rated data is of relevance when dimensioning the motor for uninterrupted duty.
NOTICE
Motor overload
An excessively high load can lead to shutdown, or if the temperature sensors are not
correctly evaluated, then the motor could be destroyed.
•
Ensure that the load does not exceed the value I
N
specified in the data sheets!
•
Ensure that the temperature sensors are correctly connected and evaluated.
Short-time duty S2
For short-time duty S2 the load duration is so short that the final thermal state is not reached.
The subsequent zero-current break is so long that the motor practically cools down
completely.
NOTICE
Motor overload
An excessively high load can lead to shutdown, or if the temperature sensors are not
correctly evaluated, then the motor could be destroyed.
•
Ensure that the load does not exceed the value I
MAX
specified in the data sheets!
•
Ensure that the temperature sensors are correctly connected and evaluated.
The motor may only be operated for a limited time t < t
MAX
with a current I
N
< I
M
≤
I
MAX
.
The time t
MAX
can be calculated using the following logarithmic formula:
with
ν
= (I
M
/ I
N
)
2
and thermal time constants t
TH
.
The thermal time constants, the maximum currents and the rated currents of the motors can
be taken from the data sheets.
The above equation is valid under the precondition that the initial temperature of the motor –
the intake temperature of the water cooling T
VORL
corresponds to what is specified in the data
sheet.
Содержание 1FW6092-2PC15-6AB3
Страница 1: ...1FW6 High Speed built in torque motors ...
Страница 2: ......
Страница 10: ...Introduction 1FW6 High Speed built in torque motors 8 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 140: ...Configuration 5 4 Mounting 1FW6 High Speed built in torque motors 138 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 298: ...Index 1FW6 High Speed built in torque motors 296 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 299: ......
Страница 300: ......