Electrical connection
8.3 System integration
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
247
The following diagram shows an example of a motor integrated into a system with the
connection of Temp-S and Temp-F via TM120. A DRIVE-CLiQ encoder is connected directly
to the TM120.
Figure 8-6
System integration with TM120 (example)
Requirements
●
The Motor Module is selected depending on the motor current at torque M
0
or according
to the maximum motor current.
●
The encoder system used must be harmonized with the particular application.
Note
Read the corresponding documentation about open-loop and closed-loop control systems.