Configuration
5.4 Mounting
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
113
5.4.2
Forces that occur between the stator and rotor
Radial and axial forces
Figure 5-12 Active forces when stators and rotors are installed
1
Rotor with permanent magnets
2
Stator
F
a
Axial attractive force
F
r
Radial attractive force
Radial forces between the stator and rotor
The following table shows the active radial forces, in N per 0.1 mm centering error, between
the stator and rotor. The longer the active component, the greater the radial force.
Table 5- 3
Radial forces in N/0.1 mm with radial centering errors during installation
Active length in mm
50
100
150
200
1FW6092
540
1060
1600
-
1FW6132
580
1140
1720
-
1FW6152
740
1490
2200
-
1FW6192
590
1200
1790
2380
1FW6232
710
1420
2130
2840
Note
You must note the radial forces between the stator and rotor as well as the maximum
permissible concentricity error specified in the dimension drawings.