background image

866.DTE.INFO (383.4636)

www.DentalEZ.com

0344

StarDental®

1816 Colonial Village Lane

Lancaster, PA 17601  U.S.A.

Printed in the U.S.A.

©2019 DentalEZ, Inc.

Emergo Europe

Prinsessegracht 20

2514 AP The Hague

The Netherlands

EC REP

StarDental®

 Instruments

Caution:

 Federal law restricts this device to 

                     sale by or on the order of a dentist.

 

065810 E  Date of Issue  2019-05-24

Titan®-E Low-Speed 

Handpiece Motor

Instruction Manual

Non-Sterile

Medical Device

Contents

Specifications

20,000 rpm Motor: 

 

StarDental

®

 Part #266131 (Fixed Back End Part #266132) 

 

• No Lubrication Required

 

• Recommended Air Pressure: 40-45 psi (swivel motor)

 

• Air Flow: 2.1 SCFM @ 40-45 psi at Maximum Power Point (swivel motor)

 

• Rotation: Forward and Reverse

 

• 4-Line Connection (Fixed Back End)

Installation

1.  Select the motor appropriate for tubing based on power requirements. Examine connection 

of the motor and swivel tubing configuration as these must match configuration of delivery 

system tubing.

Drive Air

Water

Exhaust 

Air

Air

4-Line Tubing

2/3-Line Tubing

Drive 

Air

Water

• Specifications

 

Installation

• Operation

• Cleaning & Sterilization
• Troubleshooting
• Replacement Part Numbers

• Warranty

Sterilizable up to 135°C

135°C

Titan E

20,000 rpm - Lube Free

Made in the U.S.A.

JXXXXX

®

StarDental

®

20K Motor 

(

StarDental

 Part #266131)

Swivel

BEFORE OPERATING THE MOTOR, CAREFULLY READ AND FOLLOW ALL OF THESE INSTRUCTIONS. SAVE 

THESE INSTRUCTIONS FOR FUTURE REFERENCE AND OBSERVE ALL WARNINGS AND CAUTIONS.

Indications For Use

Used intraorally by trained dental professionals for drilling and preparation of dental cavities 

for restoration, such as fillings.  The intended use extends to disking, cavity and crown preps, 

polishing, post and pin drilling and pin setting.

Swivel

Bearing Assembly

ISO Connector

Tubing 

Coupler

Tubing

2.  Disconnect  swivel  from  handpiece  if  necessary.  Grasp  the  swivel  in  front  of  the  bearing 

assembly between the thumb and index finger as shown.

3.  Slide tubing coupler until the end of the ISO connector is exposed; hold in hand as shown 

with fingers securing the tubing.

4.  Align and insert swivel tubes into the ISO connector holes.
5.  While applying slight pressure to hold fittings in the connector holes, slide coupler forward 

and engage threads. Continue threading coupler clockwise until hand tight against the swivel. 

Wrench

Tubing 

Coupler

Turn Coupler While Holding     

         Swivel in Place

6.  Using the wrench as shown, tighten the swivel to the tubing coupler. Be sure to turn tubing 

coupler, not swivel. DO NOT OVER TIGHTEN.   

Note: 

This  joint  loosens over time, resulting in loss of power.  Check  for  tightness  periodically.

7.  Connect handpiece to swivel.
8.  Using an air pressure gauge for 4-line, 

StarDental

 Part #262591, between swivel and tubing, 

obtain a reading. Adjust the air pressure at delivery head until gauge reads 40-45 psi while 

operating handpiece in full forward position and with foot control completely depressed.

Note:

 If delivery unit has oil/mist lubrication, detach and drain; handpiece needs no lubrication.

Installation - Fixed Back End Motor

Titan E

20,000 rpm - Lube Free

Made in the U.S.A.

JXXXXX

®

StarDental

®

Direction & Speed

Control Ring

Rear End Connector

20K Fixed Back End Motor 

(

StarDental

®

 Part #266132)

Note

: If delivery unit has oil/mist lubrication, detach and drain; motor is LUBE FREE.

NOTICE

 To prevent damage to bearings, before installing always check drive air pressure by 

using air pressure gauge, 

StarDental

 Part #262591 (4/6-Line) between motor and tubing and 

obtain a reading. Adjust air pressure at delivery head until gauge reads 40-45 psi while operating 

motor and with foot control completely depressed.

1.  Examine tubing. Verify tubing uses 4-Line connection.
2.  To connect motor to tubing, align drive air and exhaust tubes with mating ISO connector holes 

in coupler.

3.  While applying slight pressure to hold tubing in connector holes, slide tubing coupler forward 

and engage                                                threads. Continue threading tubing coupler clockwise until 

hand tight against the motor. DO NOT OVER TIGHTEN.

Note

:  This joint  loosens  over  time,  resulting in air leakage  and  loss of power.  Check  for  

tightness  periodically.

Operation

The 120° rotation speed adjustment ring sets direction and speed. To run motor forward at full 

speed, rotate ring towards the letter ‘F’ while operating the foot control. Rotate to the letter ‘R’ to 

yield full speed in reverse. Vary speed by rotating ring in either direction towards center. Note 

the small depression for the current setting. After setting, the motor runs at current speed and 

direction until reset. Pausing the motor is not needed to alter direction or speed using the ring.

Titan E

20,000 rpm - Lube Free

Made in the U.S.A.

JXXXXX

®

StarDental

®

Small Depression

120° Rotation Speed 

Adjustment Ring

ATTACHMENTS

The Titan-E 20K Motor is designed to work with all standard E-Type attachments.

Titan E

20,000 rpm - Lube Free

Made in the U.S.A.

JXXXXX

®

StarDental

®

Straight Nose Cone

Motor-to-Angle 

Contra-Angle Attachment

20K Titan-E Motor

ANGLE INSTALLATION

StarDental  Titan  angles  can  be  attached  to  E-Type  Motor-to-Angle 

Contra-Angle Attachments.

To install a Titan Angle:
1.  Unthread knurled ring. 
2.  Pull knurled ring enough to show splines, remove 

knuckle from angle*.

Splines

Knuckle

Knurled Ring

Titan 3 LubeFree Ball Bearing 

Auto Latch Angle Head

*

Note

:  Save the knuckle in a safe place. You will 

need the knuckle to use angle with Titan 

attachments.

Straight Nose Cone:

Attach to motor. Install bur according to manufacturer's instructions.

NOTICE

Any serious incident occurring from the use of this device should be reported to StarDental 

immediately. If incident occurred in a EU Member State the competent authority must 

be notified.

Отзывы: