8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 35
IO-Link interface
8.3.3
SICK-specific UM18-21712A21_
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
64 (0x40)
Switching point 1
UINT16
R/W
436 ... 5065
(30 ... 348 mm)
800 corresponds
to 55 mm
Specify values
as a multiple
of the internal
measurement value
resolution (0.069 mm).
65 (0x41)
Switchback point 1 UINT16
R/W
451 ... 5080
(31 ... 349 mm)
71 (0x47)
Switching point 2
UINT16
R/W
466 ... 65512
1)
(32 ... 350 mm)
72 (0x48)
Switchback point 2 UINT16
R/W
451 ... 65512
1)
(31 ... 349 mm)
73 (0x49)
Foreground
suppression
UINT8
R/W
0 ... 3246
(0 ... 223 mm)
66 (0x42)
Switching output
function
UINT8
R/W
• 00: normally closed
• 02: normally open
–
67 (0x43)
Filter
UINT8
R/W
• 00: F00
2)
• 01: F01
• 02: F02
→
68 (0x44)
Filter strength
UINT8
R/W
• 00: P00
• 01: P01
• 02: P02
• 03: P03
• 04: P04
• 05: P05
• 06: P06
• 07: P07
• 08: P08
• 09: P09
For the selected
measured value filter,
you can select a filter
strength between 0
(weak filtering effect)
and 9 (strong filtering
effect).
74 (0x4A)
Teach via pin 5 in
SIO mode
UINT8
R/W
• 00: deactivated
• 16: activated
–
Teach
Index
decimal
(hex)
Description
Access
Access
Value range
Example
Remarks
02 (0x02)
TEACH
UINT
W
• 161: Method A
• 162: Method B
• 164: Two-way
reflection barrier
• 168: Reset to
factory setting
A teach overwrites
a function that has
already been set
with a newly selected
function.
If a teach is not
successful, the old
value is retained.
→
1) Window operation deactivated for values > 5094.
2) Operation with filter setting "F00" is not permitted, as EMC faults may occur in this case.
Table 13: SICK-specific service data UM18-21112A21_