8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 43
Technical data
11.3
Power supply
11.3.1
Sensors with switching outputs
Supply voltage V
s
1)
,
sensors with switching output
UM18-2xxxxxAxxx
•
DC 15 … 30 V
Power consumption (without load)
< 1.2 W
Residual ripple
± 10 % within the acceptable supply voltage V
s
1) Limit values: Max. 8 A for operation in a short-circuit protected network.
Table 19: Supply – sensors with switching outputs
11.3.2
Sensors with analog outputs
Supply voltage V
s
1)
,
sensors with switching output
UM18-2xxxxx7xx
DC 15 ... 30 V DC
Supply voltage V
s
1)
,
sensors with switching output
UM18-2xxxxx6xx
•
DC 10 … 30 V DC at RL ≤ 100 Ω
•
DC 20 … 30 V DC at RL ≥ 100 Ω
Circuit protection
V
s
connections, reverse polarity protected
Power consumption (without load)
< 1.2 W
Residual ripple
± 10 % within the acceptable supply voltage V
s
1) Limit values: Max. 8 A for operation in a short-circuit protected network.
Table 20: Supply – sensors with analog outputs
11.4 Inputs
Multifunction input MF
• Teach-in
• communication
• Synchronization/multiplex mode
Table 21:
Inputs
11.5 Outputs
11.5.1
Sensors with switching outputs
Sensors with switching outputs
UM18-2xxxxAxxx
Switching output
• Push-pull: PNP/NPN
•
HIGH: V
s
– (< 3 V), LOW: < 3 V
• IO-Link
Содержание UM18-2 Pro