Technical data
44
© SICK AG • Subject to change without notice • 8014865/ZUJ3/2018-11-29
Hysteresis
• UM18-217xxxxxx: 2 mm
• UM18-211xxxxxx: 3 mm
• UM18-212xxxxxx: 5 mm
• UM18-218xxxxxx: 20 mm
Configurable via " Adapter"
Circuit protection
Short-circuit protected
Maximum output current
< 100 mA
Table 22: Outputs – sensors with switching outputs
11.5.2
Sensors with analog outputs
Sensors with analog outputs
• UM18-2xxxx6xxx: 4 mA … 20 mA
•
UM18-2xxxx7xxx: DC 0 … 10 V DC
Analog output
UM18-2xxxx6xxx
• 4 mA … 20 mA
•
RL ≤ 500 Ω, at V
s
≤ 20 V: max. load ≤ 100 Ω
•
Rising, falling characteristic curve, configurable
Analog output
UM18-2xxxx7xxx
•
DC 0 … 10 V DC
•
RL ≥ 100 Ω
•
Rising, falling characteristic curve, configurable
Resolution
12 Bit
Circuit protection
UM18-2xxxxx6xx: Voltage output is short-circuit protected
Table 23: Outputs – sensors with analog outputs
11.6 Interfaces
IO-Link
For sensors with switching outputs
Configuration interface for communication via " Adapter"
accessories
Table 24:
Interfaces