8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 27
Commissioning
Factory setting: Teach-in
1.
Switch off the supply voltage.
2. Apply "M" to "MF".
3. Switch on the supply voltage and wait approximately 3 seconds until
both LEDs flash simultaneously.
4.
The green LED flashes. The orange LED indicates the current setting:
• On: Teach-in
•
Off: Synchronization/multiplex mode
5.
To change the setting, apply "M" to "MF" for approximately 1 second.
The orange LED changes its status.
6.
After configuring, wait approximately 10 seconds until the green LED
stops flashing.
b
The setting has been applied. The ultrasonic sensor is in normal
operational mode.
→
For additional information about synchronization/multiplex mode and
the minimum mounting distances without synchronization/multiplex mode,
7.3.2
Resetting the settings to the factory setting
1.
Switch off the supply voltage.
2. Apply "M" to "MF".
3. Switch on the supply voltage and wait approximately 13 seconds until
both LEDs stop flashing.
4.
Before switching off the supply voltage, disconnect "M" from "MF" in
order to apply the factory setting.
b
All settings have been reset to the factory setting. The ultrasonic
sensor is in normal operational mode.