Technical data
11.7 Ambient conditions
Protection class
III
Electromagnetic compatibility
1)
EN 61000-6-2, EN 55011, Class A
EN 60947-5-2/-3
Ambient temperature range
–25 °C … +70 °C
Storage temperature range
–40 °C … +85 °C
Enclosure rating
IP 67 according to EN 60529
1) Operation with filter setting "F00" is not permitted, as EMC faults may occur in this case.
Table 25: Ambient conditions
11.8 Structural design
Dimensions
→
Weight
• Straight: 25 g
• Angled: 30 g
Materials
• Housing: Nickel-plated brass
•
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Connections
Plug M12, 5-pin
Display
• Green LED: operation
• Orange LED: on when switching/analog output is active
Table 26:
Structural design