8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 31
Commissioning
Cycle time
The cycle time corresponds to the measuring interval of the respective
sensor type.
UM18-217xxxxxx: 8 ms
UM18-211xxxxxx: 8 ms
UM18-212xxxxxx: 16 ms
UM18-218xxxxxx: 20 ms
Factory setting
•
Sensors with switching output: filter type F01 and filter strength 0
•
Sensors with analog output: filter type F02 and filter strength 1
Foreground suppression
Use foreground suppression to suppress stray reflections caused by
objects in the vicinity of the sensor.
NOTE!
Interfering objects must not create multiple reflections.
The ultrasonic sensor must not be covered by interfering
objects that affect the detection range.