Input/Output
Input Parameters
01 = Output number
Specifies which output signal to set.
0
= Out 0
1
= Out 1
2
= Out 2
02 = Type
Delay
from
trigger
When triggered by the Trigger In signal, it waits
for the
Delay time
before setting the output to
Signal Value
. After the time in
On duration
, the
signal is reversed.
How and when to trigger is set in the 'Grab
setup' tool.
Delayed
Waits for the
Delay time
before setting the
output to
Signal Value
. After the time in
On du-
ration
, the signal is reversed.
Pulse
on
Starts a pulsing output. Immediately sets the
output to high for the time in
On duration
, then
sets it to low for the time in
Off duration
. This is
repeated until a 'Set timed output' tool is exe-
cuted with
Type
set to
Pulse off
, the output
is set by another tool, or the camera is powered
down.
Pulse
off
Stops a pulsing output that has been started by
a 'Set timed output' tool with
Type
set to
Pulse on
,
Fixed
on
Immediately sets the output to high.
Fixed
off
Immediately sets the output to low.
03 = Delay time (ms)
The delay time when
Type
is set to
Delay
from
trigger
or
Delayed
. 0 – 10.000 ms.
04 = On duration (ms)
The time during which the signal is set to
Signal value
(
Type
is
Delay
from
trigger
or
Delayed
) or high (
Type
is
Pulse
on
). 0 – 10.000 ms.
05 = Off duration (ms)
The time during which the signal is set to low when
Type
is set
to
Pulse
on
. 0 – 10.000 ms.
06 = Signal value
Specifies how to set the output signal when
Type
is set to
Delay
from
trigger
or
Delayed
.
Can be set to
High
or
Low
.
Returned Values
None