Chapter
4
Reference Manual
IVC-2D
146
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
Calculation
Get Calibrated Point
The Get calibrated point tool calculates the calibrated coordinates X, Y, Z (in mm) for a
pixel in an image. The tool uses a transform created with a 'Coordinate alignment' tool and
saved in a data block on the device.
If the transform includes alignment with an external coordinate system, the tool will return
X, Y and Z coordinates, otherwise if the transform only includes coordinate calibration the Z
coordinate will always be 0.
Input Parameters
01 = Source bank
The image bank containing an image to get calibrated
coordinates from.
02 = X pixel
The x coordinate of the pixel.
03 = Y pixel
The y coordinate of the pixel.
04 = Transform data
block
The number of the data block in which the transform
to use is stored.
Returned Values
01 = Calibrated X (mm)
Calibrated X coordinate in millimeters
02 = Calibrated Y (mm)
Calibrated Y coordinate in millimeters
03 = Calibrated Z (mm)
Calibrated Z coordinate in millimeters