Reference Manual
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
249
Appendix
B
Setting Device Parameters
The parameters described in the table below are available in the dialog
Ethernet Device
Settings
:
•
Choose
Options ->
Configuration
from the IVC Studio menu bar.
•
A window containing a tree view is displayed.
•
Select
Ethernet Devices
in the tree view.
•
Ethernet devices are displayed in the right pane in the window.
•
Click the
Ethernet Device Configuration
button.
•
The Ethernet Device Settings window is displayed containing a list of available
devices.
•
Select a device from the list. The parameters in the table below are displayed for
the selected device.
Modifications to the parameters are stored in the device by clicking the “Update” button.
Please note that this will restart the device.
Parameter category
Parameter name Parameter
explanation
IP
Specifies the IP address of the
network interface. It can be set
manually or automatically
through the DHCP if this
protocol is enabled.
The number must be written in
the following format
aaa.bbb.ccc.ddd. The default
value is 192.168.0.110.
We recommend that the
number 255 is not used for
the four parts of the address
in order to avoid that the
device is not recognized.
Each device must have a
unique IP address.
Netmask
Specifies the netmask of the
sub-network. The number
must be written in the following
format aaa.bbb.ccc.ddd. The
default value is 0.0.0.0. In the
event that this parameter is
not necessary, it should be set
to 0.0.0.0 or an empty string.
Network Parameters
Gateway
Specifies the network Gateway
address. The number must be
written in the following format
aaa.bbb.ccc.ddd. The default
value is 0.0.0.0. In the event
that this parameter is not
necessary, it should be set to
0.0.0.0 or an empty string.