Reference Manual
Chapter
5
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
237
Blob Finder Setup
•
Pixels out of range are left as they are in the source bank. This simplifies threshold
tuning.
•
Pixels not part of the ROI are blue.
The image is by default stretched to fill the preview window. Click the
Fit to Window
button
to toggle between showing a stretched image and showing the image in its original size.
The stretching does not preserve the aspect ratio of the image. It is only when showing the
image in its original size that one pixel on the screen represents one pixel of the image.
Table
Use the
Table Index
to set the starting position (row number) in the table for where the
found blob centroids and areas are stored. The default value is
1000
.
This is only an extra option. All blobs are always stored internally and are thus accessible
using the ‘Blob Analyzer’ tool. Storing in the table is intended for simple applications where
only centroids and area are desired.
The
Max number of blobs in the table
limits the number of blobs that are stored in the
table. This value also determines the number of listed blobs in the Interactive Setup win-
dow, since that list uses the table values for display. If the maximum number of blobs in
the table is set to 5, then the list will contain 5 blobs as well. However, all blobs are still
stored internally.
Note: