Edge
09 = Average pixels
Number of averaged pixels for gray value.
10 = Min edge distance / Min width
Min edge distance
Number of pixels that will be skipped if a
transition is found.
Used with evaluation type relative threshold.
Min width
Number of consecutive pixels that must have
gray values between lower and upper thresh-
old.
Used with evaluation type absolute threshold.
11 = Scan interval
Distance of compared pixels (in pixels).
12 = Table index
Start index in table to write the found coordi-
nates.
13 = Max stored transitions
Upper limit for number of stored transition
coordinates in table.
Note that only transitions up to this number will
be marked with a cross in the image bank. If
Max stored transitions = 0
no found transition
will be marked in the image.
14 = Destination bank
Number of the image bank in which to display
the circle (ellipse) with red marked crosses to
indicate found transitions.
Returned Values
01 = Found transitions
Total number of found edges.
Error Messages
Error 135
The line is too short.
Error 136