Reference Manual
Chapter
4
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
165
System
Load Data Block from Flash
This tool loads data that is stored in the flash memory into a data block in the working
memory.
The data is stored in a file on the flash memory, which is referred to by the
File name
parameter.
Input Parameters
01 = File name
Name of the file to be loaded.
02 = Data block
The number of the data block in working
memory into which to load the data.
Returned Values
None
Error Messages
Err=2
A timeout occurred.
Err=159
Failed to read file from flash.