IDM 510-129-1
Maintenance
37
English language
Operation and maintenance manual
Sensitivity adjustment for the product to be wrapped detection photocell
The operation must be carried out by the maintenance technician or by per-
sonnel with suitable competences, skills and knowledge.
Make sure to fulfil the required requirements in order to work under safe con-
ditions.
– The sensitivity adjustment is required when the photocell does not detect the
presence of the load to be wrapped.
– The figure shows the points of intervention and the description shows the proce-
dures to be adopted.
1.
Mark the intervention area and
prevent access to the devices
that, if activated, may cause
unexpected hazards and jeop-
ardize the safety level.
2.
Correctly load the new product
to be wrapped in the middle of
rotating platform.
3.
Move the reel holder carriage
to match the load to be
wrapped.
4.
Check if the photocell detects
the load to be wrapped.
– The light
A
lighting up (green
light) indicates that the photo-
cell is powered.
– When pilot light
B
turns on (yel-
low light), it means that the load
to be wrapped has been detect-
ed.
– When the light
B
is off, slowly
rotate the control
C
until the in-
dicator light illuminates.
Do NOT adjust the photocell
sensibility excessively in order
to prevent it from detecting ele-
ments that are not to be wrapped.
The detection of elements that are not to wrapped can alter the point of stop of
reel holding carriage.