Maintenance
IDM 510-129-1
34
English language
Operation and maintenance manual
Cleaning and replacement of the air filter
The operation must be carried out by the maintenance technician or by per-
sonnel with suitable competences, skills and knowledge.
Make sure to fulfil the required requirements in order to work under safe con-
ditions.
– The intervention must be carried out with the machine stopped in safety condi-
tions.
– The figure shows the points of intervention and the description shows the proce-
dures to be adopted.
1.
Mark the intervention area and
prevent access to the devices
that, if activated, may cause
unexpected hazards and jeop-
ardize the safety level.
Attention
Warning
Always wear suitable personal
protective equipment in order to
avoid safety and health hazards.
2.
Rotate main disconnector to
position
“O”
(OFF) to deacti-
vate the power supply.
3.
Unhook the grid
A
.
4.
Remove the filter
B
.
5.
Clean the filter with dry com-
pressed air.
Replace the filter with an origi-
nal spare part, if it is damaged.
6.
Re-install the filter
B
.
7.
Attach the grid
A
.
–
At the end of operations,
check that there are no tools
or other material near the
moving parts or in danger-
ous areas.