![Shinko ACD-13A Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/shinko/acd-13a/acd-13a_instruction-manual_1258167065.webp)
- 65 -
Character
Setting Item, Function, Setting Range
Factory Default
Step 1 EVT4 high limit alarm value
0
• Sets Step 1 EVT4 high limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Available when the independent alarm (High/Low limits independent,
High/Low limit range independent, or High/Low limits with standby
independent) is selected in [Event output EVT4 allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT5 alarm value
0
• Sets Step 1 EVT5 alarm value.
If the independent alarm (High/Low limits independent, High/Low limit
range independent, or High/Low limits with standby independent) is
selected in [Event output EVT5 allocation], the EVT5 alarm value
matches the EVT5 low limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Not available if No event is selected in [Event output EVT5 allocation].
Available when the Alarm output is selected in [Event output EVT5
allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT5 high limit alarm value
0
• Sets Step 1 EVT5 high limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Available when the independent alarm (High/Low limits independent,
High/Low limit range independent, or High/Low limits with standby
independent) is selected in [Event output EVT5 allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 data contains data from “Step 1 SV” to “Step 1 EVT5 high limit
alarm value”.
Up to Step15 can be set repeatedly.
Step 15 EVT5 high limit alarm value
0
• Sets Step 15 EVT5 high limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Available when the independent alarm (High/Low limits independent,
High/Low limit range independent, or High/Low limits with standby
independent) is selected in [Event output EVT5 allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step SV of Steps 1 to 15 correspond to SV of Set value memory numbers 1 to 15.
EVT1 to EVT5 value of Steps 1 to 15 correspond to EVT1 to EVT5 value of Set value
memory numbers 1 to 15.