- 64 -
Character
Setting Item, Function, Setting Range
Factory Default
Step 1 EVT2 alarm value
0
• Sets Step 1 EVT2 alarm value.
If the independent alarm (High/Low limits independent, High/Low limit
range independent, or High/Low limits with standby independent) is
selected in [Event output EVT2 allocation], the EVT2 alarm value
matches the EVT2 low limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm
).
Not available if No event is selected in [Event output EVT2 allocation].
Available when the Alarm output is selected in [Event output EVT2
allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT2 high limit alarm value
0
• Sets Step 1 EVT2 high limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Available when the independent alarm (High/Low limits independent,
High/Low limit range independent, or High/Low limits with standby
independent) is selected in [Event output EVT2 allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT3 alarm value
0
• Sets Step 1 EVT3 alarm value.
If the independent alarm (High/Low limits independent, High/Low limit
range independent, or High/Low limits with standby independent) is
selected in [Event output EVT3 allocation], the EVT3 alarm value
matches the EVT3 low limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Not available if No event is selected in [Event output EVT3 allocation].
Available when the Alarm output is selected in [Event output EVT3
allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT3 high limit alarm value
0
• Sets Step 1 EVT3 high limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Available when the independent alarm (High/Low limits independent,
High/Low limit range independent, or High/Low limits with standby
independent) is selected in [Event output EVT3 allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.
Step 1 EVT4 alarm value
0
• Sets Step 1 EVT4 alarm value.
If the independent alarm (High/Low limits independent, High/Low limit
range independent, or High/Low limits with standby independent) is
selected in [Event output EVT4 allocation], the EVT4 alarm value
matches the EVT4 low limit alarm value.
Setting the value to 0 or 0.0 disables this alarm (except Process
high and Process low alarm)
.
Not available if No event is selected in [Event output EVT4 allocation].
Available when the Alarm output is selected in [Event output EVT4
allocation].
• Setting range: Refer to (Table 7.1.2-1) on p. 55.