Mode
#
Mode
Details of functions
LCD display
(Mode name)
10
Image memory
clear mode (Only
the image data is
cleared.)
This mode is used to clear the image data memory (DRAM).
10:IMAGE MEM CLEAR
14
Dial test /
adjustment mode
(Pulse 10 pps)
This mode is used to dial in dial pulse (10PPS) and to set the pulse make ratio
adjustment value.
The range of make ratio variable range: -8%
∼
+7%
The setup is reflected on the adjustment value area of the soft switch.
The dialed number is fixed to “1590.”
14:DIAL TEST 10 PPS
16
Dial test mode
(Tone)
This mode is used to dial with DTMF.
The number to be dialed is fixed to “123456789
∗
0#”.
16:DIAL TEST TONE
21
Print out soft
switch mode
This mode is used to print the report on the current soft switch setup.
21:PRINT SOFT SW
42
FAX Panel check
mode
This mode is used to check the keys and the LED on the FAX panel.
When any key on the FAX panel other than the STOP key is pressed, the name
of the pressed key is displayed on the LCD.
The LED’s on the FAX panel are lighted one by one sequentially.
When any change is made on a sensor in the SPF section, the sensor name as
well as its ON/OFF status is displayed on the LCD.
42:FAX PANEL TEST
43
Signal detect mode
This mode is used to detect signals in the line, and the detected signal name is
displayed on the LCD. The signals to be detected are CNG, DTMF, and silent.
The detection conditions conform to the soft switch setup.
43:SIG. DETECT
44
Long distance
comm. Select mode
This mode is used to specify the other party FAX numbers registered in the
one-touch/speed dial, with which communication errors occur frequently due to
poor line conditions
To the specified parties, the max. transmission speed is compulsorily reduced to
stabilize the communication line.
The speed is available in 9600BPS and 4800BPS.
44:LONG DIST COMM
C. Operating procedures in each mode
(1) Soft SW change method
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 0, 1.
SW # =
4
Enter the SW No. (2 digits) to be changed.
SW # = 10
5
Press
←
/
→
to shift the cursor to the bit to be
changed. (The left edge is Bit No. 1.)
SW10 = 00010101
bit # = 12345678
6
Press FUNCTION to highlight the bit in the
cursor position.
SW10 = 10010101
bit # = 12345678
7
Press ENTER to register.
SW # =
Return to Step 3.
Press STOP to exit from the mode.
(2) Soft switch clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 0, 2.
02:SOFT SW CLEAR
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
The soft switches setup is reset to the default,
and this mode is terminated.
FO-3800M
8 – 17
Содержание FO-3800M
Страница 115: ...S001 P001 S001 P007 CLN S001 P003 S001 P005 S001 P002 S001 P006 S001 P004 CLN FO 3800M 9 4 ...
Страница 142: ...S009 Ua002 S009 Ua003 S009 Ua004 S009 Ua005 S009 Ua006 S009 Ua001 S009 Ua001 002 S009 Ua001 001 FO 3800M 9 31 ...
Страница 174: ...SMP1 SMP2 FO 3800M 10 25 ...
Страница 175: ...SMP3 SMP4 FO 3800M 10 26 ...
Страница 176: ...SMP5 SMP6 a b D FO 3800M 10 27 ...
Страница 177: ...SMP7 SMP8 FO 3800M 10 28 ...
Страница 178: ...SMP9 SMP10 SMP11 Streaks and dots in the pitch of about 78mm Streaks and dots in the pitch of about 45mm FO 3800M 10 29 ...