Enforcement conditions (time)
Enforcement
time
JOB No
Content
S 009/Ua 002
When replacing MCU PWB.
In case of U2 trouble
When installing
When the fluorescent lamp
flickers during operation of the
copier.
Cycle
—
Condition
—
∗
Job content
1) Enter the simulation 26-30 mode.
(The currently set code of the CE mark conformity operation
(protecting against flicker) is displayed.
2) Enter the desired code (value) of the CE mark conformity opera-
tion (protecting against flicker), and press the start button.
Set code
CE mark conformity operation
(Protecting against flicker)
0
YES
1
NO
If the fluorescent lamp flickers when the power of the copier is
turned on, set this adjustment value to 1 to reduce or eliminate
this phenomenon.
SET M2
Counter setting
SET 1
Photoconductor counter reset
∗
Enforcement condition (time)
Enforcement
time
JOB No
Content
When replacing
photoconductor cartridge
S 009/Ua 002
When replacing MCU PWB
In case of U2 trouble
Cycle
20 K
Condition
—
∗
Job content
1) Turn on the power.
2) Open the operation section. (The cabinet switch is turned off.)
3) While pressing the copy mode select key (left and side) and the
clear key simultaneously, close the operation section. (The cabinet
switch is turned on.) (This state is maintained for 5 sec.)
With the above operation, the photoconductor counter is reset.
ADJ M1
Copy density adjustment
∗
Execution condition (time)
Enforcement
time
JOB No
Content
S 004
When any part of the scanner
(reading) section is
disassembled, replaced, or
cleaned.
S 009/Ua 002
When replacing MCU PWB
In case of U2 trouble
S 009/Ua 004
When replacing the high
voltage power/motor drive PWB
ADJ M6
When adjusting the high
voltage power voltage
When servicing
Cycle
—
Conditions
Normal copy exposure is not
obtained.
∗
Necessary condition
1) The scanner (reading) section must be free from dust.
2) The image process section must be normal.
★
The high voltage power voltage must be normal.
★
The photoconductor cartridge, the developer cartridge are nor-
mal (free from dirt and damage).
★
The transfer roller must be free from dirt and damage.
3) The fusing section must be normal (free from dirt).
4) The paper transport section must be normal.
5) The scan (writing) section must be free from dirt.
∗
Adjustment value (Common to all the adjustment items)
(Test command (Set value))
Range (MIN)
0
Range (MAX)
99
Standard value
50
Default
50
ADJ 1
Auto copy mode copy density adjustment
ADJ 2
Manual copy mode copy density
adjustment
ADJ 3
Photo copy mode copy density adjustment
ADJ 4
Auto (Toner save) copy mode copy
density adjustment
ADJ 5
Manual (Toner save) copy mode copy
density adjustment
(Copy density level)
Adjustment
mode
Mode display
lamp
Density
adjustment
level
SHARP gray chart
(UKOG-0062FCZZ)
adjustment level
Auto copy
mode
Auto copy
mode lamp
"3" of the gray
scale is copied.
Test copy
mode
Text copy
mode lamp
Center (3)
"3" of the gray
scale is copied.
Photo copy
mode
Photo copy
mode lamp
Center (3)
"2" of the gray
scale is copied.
Auto (Toner
save) copy
mode
Auto copy
mode lamp
"3" of the gray
scale is copied.
Photo copy
mode lamp
Manual
(Toner save)
copy mode
Manual copy
mode lamp
Center (3)
Gray scale "3" is
copied.
Photo copy
mode lamp
FO-3800M
7 – 2
Содержание FO-3800M
Страница 115: ...S001 P001 S001 P007 CLN S001 P003 S001 P005 S001 P002 S001 P006 S001 P004 CLN FO 3800M 9 4 ...
Страница 142: ...S009 Ua002 S009 Ua003 S009 Ua004 S009 Ua005 S009 Ua006 S009 Ua001 S009 Ua001 002 S009 Ua001 001 FO 3800M 9 31 ...
Страница 174: ...SMP1 SMP2 FO 3800M 10 25 ...
Страница 175: ...SMP3 SMP4 FO 3800M 10 26 ...
Страница 176: ...SMP5 SMP6 a b D FO 3800M 10 27 ...
Страница 177: ...SMP7 SMP8 FO 3800M 10 28 ...
Страница 178: ...SMP9 SMP10 SMP11 Streaks and dots in the pitch of about 78mm Streaks and dots in the pitch of about 45mm FO 3800M 10 29 ...