4. FAX simulations
A. Entering the FAX simulation mode
There are following two ways of entering the Fax simulation mode. They differ only in the key sequence and the operations of the simulation are
the same in either mode.
For key operations in the FAX simulation mode, use the LCD display and the FAX panel.
During Fax operations, the Fax simulation cannot be entered.
(1) From the FAX panel
Procedure
Procedure Position
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
Fax Panel
ROM version is displayed on the LCD.
2
Press ENTER.
Fax Panel
FAX enters the simulation mode.
The machine is in the normal display.
3
Press
←
/
→
proper times.
Fax Panel
Each mode name is displayed on the LCD sequentially.
4
Press ENTER.
Fax Panel
The mode is determined.
5
Procedure in each mode
Fax Panel
Operations in each mode
Instead of above procedures 3 and 4, press the code (2 digits) of the target mode to enter the mode directly.
(2) From the COPIER panel
Procedure
Procedure Position
Operation
1
Press Clear, Exposure, Clear,
Exposure.
Copier Panel
Waiting for simulation code.
FAX is in the normal display.
2
Enter the main code of 66 with
10Up/1Up keys.
Copier Panel
“66” is displayed on 7SEG LED.
3
Press START key.
Copier Panel
The machine exits the simulation mode, and the FAX enters the
simulation mode.
4
Press
←
/
→
proper times.
Fax Panel
Each mode name is displayed on the LCD sequentially.
5
Press ENTER.
Fax Panel
The mode is determined.
6
Procedure in each mode
Fax Panel
Operations in each mode
Instead of above procedures 4 and 5, press the code number (2 digits) of the target mode to enter the mode directly.
B. List of functions
Mode
#
Mode
Details of functions
LCD display
(Mode name)
01
Soft switch setting
mode
This mode is used to change the soft switch setup. The available soft switches
are SW1 to SW30. The contents of soft switches are backed up.
For details of soft switches, refer to “Software Switch for FAX.”
01:SOFT SWITCH
02
Soft switch clear
mode (Only the
setup is cleared.)
This mode is used to reset the soft switch setup (including the user option setup)
to the default.
Since, however, some of soft switches have the adjustment values, the area for
the adjustment values is excluded from the targets.
02:SOFT SW CLEAR
03
ROM & RAM
check mode
This mode is used to perform ROM check sum and RAM read/write test.
The result is shown with the buzzer and the LCD.
No error: NO ERROR/ No buzzer
ROM error
: ROM ERROR / Buzzer once
RAM error
: RAM ERROR / Buzzer twice
03:ROM/RAM CHECK
04
Signal send mode
This mode is used to send various signals to the line. The FAX signal is sent in
the level set with the soft switch.
There are the following kinds of signals:
04:SIGNAL SEND
1
No signal ( OFF HOOK state)
2
DTMF
(0,1,2,3,4,5,6,7,8,9,
∗
,#)
3
14400 bps (V.17)
(00000000b, 11111111b, 01010101b)
4
12000 bps (V.17)
(00000000b, 11111111b, 01010101b)
5
9600 bps (V.17)
(00000000b, 11111111b, 01010101b)
6
7200 bps (V.17)
(00000000b, 11111111b, 01010101b)
7
9600 bps (V.29)
(00000000b, 11111111b, 01010101b)
8
7200 bps (V.29)
(00000000b, 11111111b, 01010101b)
9
4800 bps (V27ter)
(00000000b, 11111111b, 01010101b)
10
2400 bps (V27ter)
(00000000b, 11111111b, 01010101b)
11
300 bps (FLAG)
(00000000b, 11111111b, 01010101b)
12
2100 Hz (CED)
13
1100 Hz (CNG)
FO-3800M
8 – 16
Содержание FO-3800M
Страница 115: ...S001 P001 S001 P007 CLN S001 P003 S001 P005 S001 P002 S001 P006 S001 P004 CLN FO 3800M 9 4 ...
Страница 142: ...S009 Ua002 S009 Ua003 S009 Ua004 S009 Ua005 S009 Ua006 S009 Ua001 S009 Ua001 002 S009 Ua001 001 FO 3800M 9 31 ...
Страница 174: ...SMP1 SMP2 FO 3800M 10 25 ...
Страница 175: ...SMP3 SMP4 FO 3800M 10 26 ...
Страница 176: ...SMP5 SMP6 a b D FO 3800M 10 27 ...
Страница 177: ...SMP7 SMP8 FO 3800M 10 28 ...
Страница 178: ...SMP9 SMP10 SMP11 Streaks and dots in the pitch of about 78mm Streaks and dots in the pitch of about 45mm FO 3800M 10 29 ...