(2) Simulation list
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
Used to check the operations of the scanner (reading)
unit and its control circuit.
Operation test/check
Optical (Image
scanning)
Operation
2
2
Used to check the operations of the sensors and
detectors in the SPF unit and the related circuit.
Operation test/check
ADF/RADF/UDH/SPF
Operation
3
Used to check the operations of the RADF/ADF/SPF
unit motors and their control circuits.
Operation test/check
ADF/RADF/UDH/SPF
Operation
4
Used to check the operations of the loads (solenoids)
in the RADF/ADF/SPF units and their control circuits.
Operation test/check
ADF/RADF/UDH/SPF
Operation
5
1
Used to check the operations of the operation panel
display lamps and their control circuits.
Operation test/check
Operation (Display/
Operation key)
Operation
2
Used to check the operations of the heater lamp and
the control circuit. Used to check the operations of the
fan motor and the control circuit.
Operation test/check
Fixing (Fusing)
Operation
3
Used to check the operations of the copy lamp and
the control circuit.
Operation test/check
Optical (Image
scanning)
Operation
6
1
Used to check the operations of the paper feed (clutch
and solenoid) and the control circuits.
Operation test/check
Paper transport
Operation
7
1
Used to check the warm-up time and the operations of
all the units and to make copy aging. This allows to
check the operation of each section during copying.
Operation test/check
Operation
6
Used to check the warm-up time and the operations of
all the units and to make copy aging (intermittent
operation). This allows to check the operation of each
section during copying.
Operation test/check
Operation
8
1
Used to check the operations of the developing bias
voltage and the transfer charger voltage and their
control circuits.
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
2
Used to check adjust the operations of the developing
bias voltage, the main charger voltage, and the
transfer charger voltage and their control circuits.
Adjustment/
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
3
Used to check the operations of the main charger
voltage and the control circuit.
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
14
0
Used to cancel a self diag trouble other than U2
trouble.
Clear/Cancel (Trouble
etc.)
Trouble
Error
16
0
Used to cancel the self diag trouble U2 trouble.
Clear/Cancel (Trouble
etc.)
Memory
Trouble
Error
22
4
Used to check the number of total mis-feed (jam) in
the machine.
Operation data output/
Check (Display/Print)
Trouble
Misfeed
5
Used to check the total count number.
User data output/
Check (Display/Print)
Counter
Total
8
Used to check the umber of use of the SPF.
Operation data output/
Check (Display/Print)
ADF/RADF/UDH/SPF
Counter
ADF/RADF/
UDH/SPF
12
Used to check the print count number of the OPC
drum.
Operation data output/
Check (Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Photo
conductor
Counter
14
Used to check the ROM version.
Others
Software
17
Used to check the copy count number.
Operation data output/
Check (Display/Print)
Counter
Copier
18
Used to check the print count number.
Operation data output/
Check (Display/Print)
Counter
Printer
20
Used to check the FAX print count number.
Operation data output/
Check (Display/Print)
FAX
Counter
Printer
21
Used to check the frequency of use (scanning) of the
scanner (reading).
Operation data output/
Check (Display/Print)
Optical (Image
scanning)
Counter
Scanner
22
Used to check the total mis-feed (jam) number of the
SPF.
Operation data output/
Check (Display/Print)
ADF/RADF/UDH/SPF
Trouble
Misfeed
23
Used to check the frequency of use of FAX
(reception). (FAX model only)
Operation data output/
Check (Display/Print)
FAX
Counter
Communication
24
Used to check the frequency of use of FAX
(transmission). (FAX model only)
Operation data output/
Check (Display/Print)
FAX
Counter
24
1
Used to clear the mis-feed (jam) counter in the
machine.
Data clear
Counter
4
Used to clear the SPF counter.
Data clear
ADF/RADF/UDH/SPF
Counter
7
Used to clear the OPC drum counter.
Data clear
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Photo
conductor
Counter
8
Used to clear the copy counter.
Data clear
Counter
Copier
9
Used to clear the print counter.
Data clear
Counter
Printer
FO-3800M
8 – 3
Содержание FO-3800M
Страница 115: ...S001 P001 S001 P007 CLN S001 P003 S001 P005 S001 P002 S001 P006 S001 P004 CLN FO 3800M 9 4 ...
Страница 142: ...S009 Ua002 S009 Ua003 S009 Ua004 S009 Ua005 S009 Ua006 S009 Ua001 S009 Ua001 002 S009 Ua001 001 FO 3800M 9 31 ...
Страница 174: ...SMP1 SMP2 FO 3800M 10 25 ...
Страница 175: ...SMP3 SMP4 FO 3800M 10 26 ...
Страница 176: ...SMP5 SMP6 a b D FO 3800M 10 27 ...
Страница 177: ...SMP7 SMP8 FO 3800M 10 28 ...
Страница 178: ...SMP9 SMP10 SMP11 Streaks and dots in the pitch of about 78mm Streaks and dots in the pitch of about 45mm FO 3800M 10 29 ...