AR-6020V SIMULATIONS 6-15
1
1
43
02
<20/23 CPM only>
Fusing temperature setting 2
<Fusing temperature setting 2>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
*1: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 16, becomes 230 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 6, becomes 180 degree C.
Table 1
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
03
<20/23 CPM only>
Fusing temperature setting 3
<Fusing temperature setting 3>
With the simulation executed, the current setup values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
*1: As the setup value is increased by 1, the target temperature is increased by 10 degree C.
(See Table 2.) The temperature for the default, 3, becomes 110 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 2, becomes 160 degree C.
*3: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 0, becomes 150 degree C.
Table 1
Table 2
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents
Details of operation
Display
lamp
Contents
Setting Display Setup range Reference
Default
1
Alarm Stop change TH_US temperature
O
O
Table1
M
16
2
Alarm Stop release TH_US temperature
O
O
Table1
N
6
3
After rotating time when a job is completed
O
O
0 - 90
O
0
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Temperature
(Degree C)
150
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
230
Display
lamp
Contents
Setting Display
Setup
range
Reference
Default
1
Preheating TH_UM set value
O
O
Table2
S
2
2
TH_UM set value when Warm-Up at 120 degree C
or below
O
O
Table1
T
3
3
TH_UM set value when Warm-Up at 120 degree C
or above
O
O
Table1
Y
0
4
Warm-Up completion time when Warm-Up at alpha
degree C or above
O
O
0 - 90
AB
23
5
TH_UM set value when Warm-Up at alpha degree
C or above
O
O
Table1
AC
2
6
Threshold value alpha when applying the AB to AC.
O
O
50 - 90
AD
70
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Temperature
(Degree C)
150
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
230
No.
0
1
2
3
4
5
6
7
8
Temperature
(Degree C)
80
90
100
110
120
130
140
150
160
1
: ‘19/Oct.