AR-6020V SIMULATIONS 6-16
1
43
04
<20/23 CPM>
Fusing temperature setting 4
<Fusing temperature setting 4>
When this simulation is executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
*1: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 3.) The temperature for the default, 5, becomes 5 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 3.) The temperature for the default, 3, becomes -5 degree C.
*3: Correction temperature from starting a JOB to reaching the JOB initial temperature correction no.
of sheets
*4: Correction temperature from starting a JOB to reaching the JOB latter-half temperature correction
no. of sheets
Table 3
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
<26/31 CPM>
Fusing temperature setting 2
<Fusing temperature setting 2>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents
Details of operation
Display
lamp
Contents
Setting Display
Setup
range
Reference Default
1
Ready standby TH_UM set value [L environment]
O
O
0 - 99
A
60
2
Black-White plain paper TH_UM set value [L envi-
ronment]
O
O
0 - 99
C
55
3
Thin paper TH_UM set value [L environment]
O
O
0 - 99
D
55
4
Heavy paper1 TH_UM set value [L environment]
O
O
0 - 99
E
55
5
Heavy paper2 TH_UM set value [L environment]
O
O
0 - 99
F
55
6
Label paper TH_UM set value [L environment]
O
O
0 - 99
G
55
7
OHP TH_UM set value [L environment]
O
O
0 - 99
H
55
8
Envelop 1 - 9 TH_UM set value [L environment]
O
O
0 - 99
I
55
9
MM prior rotation start TH_UM set value [L environ-
ment]
O
O
0 - 99
J
50
10
MM prior rotation end TH_EX set value [L environ-
ment]
O
O
0 - 99
K
56
11
Warm-up complete time [L environment]
O
O
0 - 99
L
50
12
Alarm Stop change TH_US temperature [L environ-
ment]
O
O
0 - 99
M
50
13
Alarm Stop release TH_US temperature [L environ-
ment]
O
O
0 - 99
N
50
14
After rotating time when a job is completed [L envi-
ronment]
O
O
0 - 99
O
50
15
Preheating TH_UM set value [L environment]
O
O
0 - 99
S
50
16
TH_UM set value when Warm-Up at 120 degree C
or below [L environment]
O
O
0 - 99
V
55
17
TH_UM set value when Warm-Up at 120 degree C
or above [L environment]
O
O
0 - 99
Y
55
18
Warm-Up completion time when Warm-Up at alpha
degree C or above [L environment]
O
O
0 - 99
AB
50
19
TH_UM set value when Warm-Up at alpha degree
C or above [L environment]
O
O
0 - 99
AC
55
20
Threshold value alpha when applying the AB to AC.
[L environment]
O
O
30 - 70
AD
50
No.
0
1
2
3
4
5
6
7
8
Temperature
(Degree C)
-20
-15
-10
-5
0
5
10
15
20
Display
lamp
Contents
Setting Display
Setup
range
Reference
1
Black-White plain paper duplex TH_UM set value
O
O
70
-
220
A
2
Black-White plain paper duplex TH_US set value
O
O
70
-
220
B
3
Applicable paper quantity of Black-White plain paper duplex
O
O
0
-
255
C
4
Black-White heavy paper duplex TH_UM set value
O
O
70
-
220
D
5
Black-White heavy paper duplex TH_US set value
O
O
0
-
200
E
6
Applicable paper quantity of Black-White heavy paper duplex
O
O
0
- 25
5
F
1
: ‘19/Oct.