AR-6020V DISASSEMBLY AND ASSEMBLY 10 – 20
2) By following the figure in below, attach the DV side sheets.
<DV side sheets attachment reference>
(4) Developing cartridge
1) Remove the cartridge guide unit.
(5) Developing doctor
1)
Remove the developing doctor by removing the doctor cover
and screws in order as shown in the figure.
(6) MG roller
1)
Remove the DV cover F.
2)
Remove the MG roller by removing the screws, the earth cable
, the spring and the MG pulley in order as shown in the figure.
Clearance with the
molt edge.
Must not be covered.
Attach with the
projection (rib)
reference
Attach with the
line (mark-off line)
reference.
0
0
0.5
0.3
0
0
0.3
0.5
(When viewed from the front)
(When viewed from the front)
Side molt F
Clearance with the
molt edge.
Must not be covered.
Molt edge
reference
DV Side
sheet F
Side molt R
Molt edge
reference
DV Side
sheet R
(2)
(3)
(3)
(3)
(4)
(1)
(4)
(3)
(2)
(2)