AR-6020V SIMULATIONS 6-27
51
09
DHV ON/OFF timing adjustment
When this simulation is executed, the current set value is displayed on the number of copies display.
*
Enter the adjustment value with the Numeric keys and press the [START] key, and the entered number is
written into the EEPROM and the machine goes into the sub code entry standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is displayed on the
number of copies display.
When the [INTERRUPT] key is pressed at that time, machine goes into the sub code input standby mode. When
the [CA] key is pressed, the simulation mode is terminated.
20
Polygon motor stop operation
adjustment
When this simulation is performed, the current setting code number is displayed. When the code number is entered
and the [START] key is pressed, the setting is changed.
21
1CS pick up roller adjustment
When this simulation is performed, the current setting code number is displayed. When the code number is
entered and the [START] key is pressed, the setting is changed.
53
06
RSPF scanning width detection
adjustment
When the guide of the RSPF tray is opened in the maximum width and the [START] key is pressed, the current AD
value is saved in the RAM temporarily.
After adjusting the maximum width, the [AUTO] indicator lights and the start of the P1 width (A4R) is displayed.
When the [TEXT] indicator lights and the start of the P2 position (A5R) is displayed.
When the [PHOTO] indicator lights and the start of the MIN position is displayed.
After finishing the adjustment, the [DATA NOTIFICATION] indicator lights and the setting of the RAM is saved in the
EEPROM.
When the adjustment is failed to finish, the [ERROR] indicator flashes and the setting is not saved in the EEPROM.
In this case, the adjustment has to be done again.
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the sub code entry
standby mode. When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
07
RSPF scanning width detection check
and setting
When this simulation is executed, the current set value is displayed on the number of copies display.
*
Enter the adjustment value with the Numeric keys and press the [START] key, and the entered number is
written into the EEPROM and the machine goes into the sub code entry standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is displayed on the
number of copies display.
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the sub code entry
standby mode. When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
08
RSPF scanning position automatic
adjustment
(Only when the RSPF is installed)
RSPF scanning position automatic adjustment
When this simulation is executed, the current set value is displayed on the number of copies display.
* Enter the adjustment value with the Numeric keys and press the [START] key, and the entered number is written
into the EEPROM.
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
* When the adjustment value of the RSPF reading start position is increased by 1, the distance to the RSPF reading
start position is advanced. (Adjustment range: 1 - 99)
* When the adjustment value is increased by 1, the position is advanced in 0.1mm.
60
01
SDRAM (image memory area) access
check
Access check to the SDRAM is made.
When this simulation is executed, the SDRAM check is started. Fusing execution. the start LED turns OFF. If an
error occurs, the following LED turns ON. When the operation is normally completed, the START indicator is turned
ON.
After completion of checking, press [CA] key to reboot the machine.
61
01
LSU operation check
When the [START] key is pressed, start confirming the operation of the polygon motor and the BD.
During the confirmation, the sub code is displayed. When this confirmation is finished, the result is displayed.
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the sub code entry
standby mode. When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
Main
code
Sub
code
Contents
Details of operation
LED
Adjustment mode
Default
AUTO indicator
TEXT indicator
DHV ON timing
DHV OFF timing
50
50
No.
Contents
0
1
The polygon motor is stopped after the operation is finished in 30 seconds.
The polygon motor is stopped right after the operation is finished.
No.
Contents
0
1
Only the smallest roller is activated. (ON)
Setting roller is activated. (ON).
LED
Display mode
ALL indicators OFF
AUTO indicator
TEXT indicator
PHOTO indicator
MAX position
P1 position
P2 position
MIN position
LED
Display mode
AUTO indicator
TEXT indicator
Write end error
Read end error
LED
Display mode
DATA NOTIFICATION indicator
AUTO indicator and ERROR indicator
TEXT indicator and ERROR indicator
PHOTO indicator and ERROR indicator
Finish completely
PM error
BD error
LD degradation error