AR-6020V SIMULATIONS 6-19
44
10
Process control data display 2
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the negative value is displayed, the [Developer replacement required] indicator lights.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
11
Process control data display 3
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
12
Process control data display 4
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents
Details of operation
No.
Contents
Setting
Display
Range
Default
1
Laser power default value (CP) (TSOFF)
-
O
0 - 255
112
2
Laser power default value (PRT) (TSOFF)
-
O
0 - 255
112
3
Corrected laser power default value (CP) (TSOFF)
-
O
0 - 255
112
4
Corrected laser power default value (PRT) (TSOFF)
-
O
0 - 255
112
5
Laser power default value (CP) (TSON)
-
O
0 - 255
112
6
Laser power default value (PRT) (TSON)
-
O
0 - 255
112
7
Corrected laser power default value (CP) (TSON)
-
O
0 - 255
112
8
Corrected laser power default value (PRT) (TSON)
-
O
0 - 255
112
9
Dissolution laser power correction value (CP)
-
O
-127 - 127
0
10 Dissolution laser power correction value (PRT)
-
O
-127 - 127
0
11 Environmental laser power correction value (CP)
-
O
-127 - 127
0
12 Environmental laser power correction value (PRT)
-
O
-127 - 127
0
No.
Contents
Setting
Display
Range
Default
1
Temperature/humidity area for toner control
-
O
1 - 8
8
2
Temperature AD value for toner control
-
O
0 - 1023
466
3
Humidity AD value for toner control
-
O
0 - 1023
7
4
Temperature AD value for transfer printing
-
O
0 - 1023
0
5
Humidity AD value for transfer printing
-
O
0 - 1023
0
6
Temperature/humidity area for transfer printing
-
O
1 - 8
8
No.
Contents
Setting
Display
Range
Default
1
Dissolution drum travel distance area
-
O
1 - 15
0
2
Developer life area for process unit
-
O
0 - 15
0
3
Environmental correction area
-
O
1 - 8
8
4
Duplex printing counter
-
O
0 - 300
8
5
Laser power area
-
O
0 - 15
0
6
Laser power environmental area
-
O
0 - 8
7
8
Machine model type
-
O
0 - 1
0