AR-6020V SIMULATIONS 6-8
22
06
Developing counter display
The developing counter data is acquired and displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
07
Mini maintenance preset display (Valid
only when the destination is set to
Japan AB series)
The mini maintenance cycle data is acquired and displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08
RSPF counter display
The RSPF counter value is displayed. (Three digits are displayed alternatively.)
09
Paper feed counter display
The counter value of the selected paper feed section is acquired from each variable, the data is displayed on the
number of copies display according to the regulations. When this simulation is executed, the value of the 1st paper
tray is displayed first. Press the [TRAY SETTING] key to select the tray. When the [INTERRUPT] key is pressed,
the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
10
Developer counter display
The developer counter value is displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
14
P-ROM version display
The P-ROM version is displayed on the number of copies display The main code and the sub code are alternatively
displayed by 2 digits. The display interval is same as that of the counter display. By pressing the [AUTO/TEXT/
PHOTO] key, the display of the version is changed.
*1: Only when the NNB is installed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
15
Trouble memory display
The trouble codes are acquired from the trouble memory data.
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed on the 1st ~
2nd digit.
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10).
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
When the [START] key is pressed, the sub code is displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.
16
Duplex print counter display
(Duplex model only)
Data is acquired from the duplex print counter variable, and is displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
17
Copy counter display
The copy counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub code
input standby mode. When the [CA] key is pressed, the simulation is terminated.
18
Printer counter display
The printer counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub code
input standby mode. When the [CA] key is pressed, the simulation is terminated.
19
Scanner mode counter display
The scanner mode counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub
code input standby mode. When the [CA] key is pressed, the simulation is terminated.
22
RSPF jam counter display
(Only when the RSPF is installed)
The RSPF jam counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub
code input standby mode. When the [CA] key is pressed, the simulation is terminated.
50
Developer rotation time display
The developer counter and rotation distance and rotation number is displayed. (Three digits are displayed
alternatively.) By pressing the [AUTO/TEXT/PHOTO] key, the display of the version is changed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
51
Drum rotation time display
The drum counter and rotation distance and rotation number is displayed. (Three digits are displayed alternatively.)
By pressing the [AUTO/TEXT/PHOTO] key, the display of the version is changed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
52
Toner rotation time display
The toner counter and the rotation number is displayed. (Three digits are displayed alternatively.) By pressing the
[AUTO/TEXT/PHOTO] key, the display of the version is changed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
Main
code
Sub
code
Contents
Details of operation
LED
Displayed version
TEXT indicator
Machine program
PHOTO indicator
NNB Program *1
LED
Displayed version
AUTO indicator
TEXT indicator
PHOTO indicator
Developer counter
Rotation distance
Rotation number
LED
Displayed version
AUTO indicator
TEXT indicator
PHOTO indicator
Drum counter
Rotation distance
Rotation number
LED
Displayed version
AUTO indicator
TEXT indicator
Toner counter
Rotation number