AR-6020V MAINTENANCE 9 – 6
4.Maintenance display system
*1: Installation of a new toner cartridge allows to display the remaining quantity.
5.Note for replacement of consumable
parts
A.Toner cartridge
When a waste toner cartridge is removed from the machine, it must
be put it must be put in a box.
B. DV cartridge
Do not shake or put up the developer cartridge. Otherwise devel-
oper may scatter.
Toner
Life
Toner save OFF : 20K/8.4K / Toner save ON : 23K/10K
Remaining quantity check
Hold down the [Light] key, and hold down the [%] key for more than 5 sec The remaining quan-
tity will be displayed on the LCD.
Remaining quantity display levels : 100%, 75%, 50%, 25%, 10, Lo
Remaining quantity
NEAR END (Toner remaining quantity : 0%)
TONER END
(Remaining printable sheets around 50 sheets ) *1
Display and icon of LCD
(Panel Display (Indicator : Toner cartridge
replacement required indicator, Red LED))
Light
Blink
Machine operation
Operation allowed
Stop
SIM22-52 Toner rotation time display
Developer
Life
20, 23cpm : 75K / 26, 31cpm : 100K or 550K rotation
Display and icon of LCD
(Panel Display (Indicator : Developer
replacement required indicator, Red LED))
Light
Machine operation
It is possible to set to stop at drum life over by SIM26-37.
0 : Stop at drum life over, 1 : Cancel of stop at drum life over
(When "0" is selected in SIM26-37, the indicator and the LED blink and stop the operation with ;
20, 23cpm 75K / 26, 31cpm 100K.
Default : 20, 23cpm 75K / 26, 31cpm 100K
SIM22-6 Developing counter display
SIM22-50 Developer rotation time display
Clear the counter by Sim25-2 (Auto developer adjustment Sheets, travel distance and rotation
number are cleared.)
Maintenance
Display and icon of LCD
(Panel Display (Indicator : Maintenance
indicator, Red LED))
Light
Setting
100K, 75K, 50K, 10K, 7.5K, 5K and Free (no LED) can be selected by SIM21-1.
Default : 20, 23cpm 75K / 26, 31cpm 100K.
SIM20-1 Maintenance counter clear
SIM22-1Maintenance counter display
SIM22-2 Maintenance preset display
Machine operation
Does not stop
It is possible to set to stop at drum life over by SIM26-36.
0: Stop at developer life over, 1 : Cancel of stop at developer life over
*1 This is just a reference. The printing result could be changed depending on the usage conditions.