5
Electrical installation
Installation topology (example: standard installation)
Operating Instructions – MOVIGEAR
®
performance
74
5.4
Installation topology (example: standard installation)
The
following
figure
shows
a
basic
installation
topology
with
MOVIGEAR
®
performance:
MOVIGEAR
®
MOVIGEAR
®
MOVIGEAR
®
Safety relay
24 V
Supply system Controller
Back-up
fuse/line
protection
Control cabinet level
Field level
Supply system
Fieldbus [1]
STO [2]
Backup mode
[3]
[4]
[4]
[4]
24 V
DFC.0..
DFC.0..
DFC.0..
9007224521510283
[1]
The maximum permitted cable length of the Ethernet fieldbus cable between the
drive units is 100 m. The maximum permitted cable length between controller
and drive unit is 100 m. The permitted length might be less due to the technical
data of the controller.
[2]
The maximum permitted length of the STO cable between the safety relay and
the last drive unit is 100 m.
[3]
The drive unit is equipped with an integrated DC 24 V supply. As an option, the
electronics of the drive unit may be supported by an external DC 24 V supply.
[4]
Electronics cover DFC.0.. with 2 x M12 fieldbus connection
25945475/EN – 04/2019