8
Service
Fault messages with parameterizable response
Operating Instructions – MOVIGEAR
®
performance
152
Fault
Description
Index
no.
Possible fault response
Electromechanical capa-
city utilization – prewarn-
ing
Here you can set the device re-
sponse to an exceeded prewarning
threshold for electromechanical ca-
pacity utilization (index 8336.2).
8622.10
•
No response
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
HW limit switches – cur-
rent parameter set
8572.1
•
No response
•
Emergency stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit) with self-
reset
SW limit switches – cur-
rent parameter set
8572.2
•
No response
•
Emergency stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit) with self-
reset
Encoder – warning
Here you can set the device re-
sponse to an encoder warning.
8622.13
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Encoder – fault
Here you can set the device re-
sponse to an encoder fault.
8622.14
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage
Application heartbeat
timeout
(only with DSI designs)
Here you can set the device re-
sponse to a timeout of the applica-
tion heartbeat.
8622.21
•
Warning
•
Application stop (with out-
put stage inhibit)
•
Emergency stop (with out-
put stage inhibit)
•
Inhibit output stage