8
Service
Extended storage
Operating Instructions – MOVIGEAR
®
performance
280
Climate zone
Packaging
1)
Storage location
2)
Storage duration
Tropical (Asia,
Africa, Central
and South
America, Aus-
tralia, New
Zealand ex-
cluding tem-
perate zones)
Packed in containers,
with desiccant and
moisture indicator
sealed in plastic wrap.
Protected against in-
sect damage and mil-
dew by chemical treat-
ment.
Under roof, protected against rain and
shocks.
Up to 3 years with regu-
lar checks of the pack-
aging and moisture in-
dicator (relative humid-
ity < 50%).
Open
Under roof and enclosed at constant
temperature and atmospheric humidity
(5 °C < ϑ < 50 °C, < 50% relative hu-
midity).
No sudden temperature fluctuations.
Controlled ventilation with filter (free
from dust and dirt). No aggressive va-
pors, no shocks. Protected against in-
sect damage.
2 years or more with
regular inspections.
Check for cleanness
and mechanical dam-
age during the inspec-
tion. Check corrosion
protection.
1) The packaging must be carried out by an experienced company using the packaging materials that have been explicitly specified for
the particular application.
2) SEW‑EURODRIVE recommends storing the drive according to the mounting position.
8.13.3
Electronics
INFORMATION
For electronics components, adhere to the following notes in addition to the notes in
chapters "Extended storage" > "Drive" and "Extended storage" > "Storage condi-
tions".
If the device is in extended storage, connect it to the line voltage for at least 5 minutes
every 2 years. Otherwise, the device's service life may be reduced.
Procedure in case maintenance has been neglected
Electrolytic capacitors are used in the inverters. They are subject to aging effects
when de-energized. This effect can damage the capacitors if the device is connected
directly to the nominal voltage after a longer period of storage. If you have not per-
formed maintenance regularly, SEW‑EURODRIVE recommends that you increase the
line voltage slowly up to the maximum voltage. This can be done, for example, by us-
ing a variable transformer for which the output voltage has been set according to the
following overview. After you have completed the regeneration process, the device
can be used immediately or stored again for an extended period with maintenance.
The following graduations are recommended:
AC 400/500 V units:
•
Stage 1: AC 0 V to AC 350 V within a few seconds
•
Stage 2: AC 350 V for 15 minutes
•
Stage 3: AC 420 V for 15 minutes
•
Stage 4: AC 500 V for 1 hour