8
Service
Fault table CiA402 profile
Operating Instructions – MOVIGEAR
®
performance
263
Subfault: 32.8
Description: User-timeout timeout
Response: User timeout timeout response
Cause
Measure
The timeout time of the user timeout function
elapsed.
Write the parameter for triggering the user
timeout function cyclically before the timeout time
elapses.
Subfault: 32.11
Description: Local mode timeout
Response: Local mode – timeout response
Cause
Measure
Communication connection to device interrupted
in local mode.
– Increase the timeout setting in local mode.
New Scope project created.
– Reset the fault.
– Restart local operation.
Scope measurement loaded from device.
– Reset the fault.
– Restart local operation.
Subfault: 32.12
Description: Manual mode timeout
Response: Manual mode – timeout response
Cause
Measure
Communication connection to device interrupted
in manual mode.
– Check whether too many programs are open on
the operator PC.
– Increase the timeout time in manual mode.
New Scope project created.
– Reset the fault.
– Restart manual operation.
Scope measurement loaded from device.
– Reset the fault.
– Restart manual operation.
8.8.26
Fault 33 System initialization
Subfault: 33.1
Description: Motor current measurement
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Motor current measurement detected an error.
Contact SEW-EURODRIVE Service.