8
Service
Fault table CiA402 profile
Operating Instructions – MOVIGEAR
®
performance
243
Subfault: 18.10
Description: Watchdog
Response: Output stage inhibit
Cause
Measure
Software no longer operates within intended cycle
time.
– Switch the device off and on again.
– Contact SEW‑EURODRIVE Service if the error
persists.
Subfault: 18.12
Description: Configuration data
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Configuration data not plausible or cannot be in-
terpreted by active firmware version.
Update the firmware or load valid configuration
data.
Subfault: 18.13
Description: Calibration data
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Calibration data not plausible.
Load valid calibration data.
8.8.15
Fault 19 Process data
Subfault: 19.1
Description: Torque setpoint violation
Response: Application stop + output stage inhibit
Cause
Measure
Implausible values specified as torque setpoints.
Adjust torque setpoints.
Subfault: 19.2
Description: Position setpoint violation
Response: Application stop + output stage inhibit
Cause
Measure
Position setpoint outside software limit switches.
Check the position setpoint.
Position setpoint outside modulo range.
Check the position setpoint.
Position in user unit generates number overflow
in the system unit.
Check the position in user unit.