5
Electrical installation
Installation planning taking EMC aspects into account
Operating Instructions – MOVIGEAR
®
performance
65
5
Electrical installation
INFORMATION
Adhere to the safety notes during installation.
5.1
Installation planning taking EMC aspects into account
5.1.1
Notes on arranging and routing installation components
The correct operation of decentralized inverters depends on selecting the correct
cables, providing correct grounding, and on a properly functioning equipotential bond-
ing.
Always adhere to the
relevant standards
.
Note the following information.
5.1.2
EMC-compliant installation
INFORMATION
This drive system is not designed for operation on a public low voltage supply system
that supplies residential areas.
This is a product with restricted availability in accordance with IEC 61800-3. This
product may cause EMC interference. In this case, it is recommended for the user to
take suitable measures.
With respect to the EMC regulation, frequency inverters and compact drives cannot be
seen as stand-alone units. They can only be evaluated in terms of EMC when they are
integrated in a drive system. Conformity is declared for a described, CE-typical drive
system. These operating instructions contain further information.
5.1.3
Cable selection, routing and shielding
WARNING
Electric shock caused by faulty installation.
Severe or fatal injuries.
•
Take the utmost care when installing the units.
•
Observe the connection examples.
For more information on cable selection, routing and shielding, refer to chapter "Cable
routing and shielding".
25945475/EN – 04/2019
Содержание Movigear Performance MGF**-DFC-C Series
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 412: ......
Страница 413: ......
Страница 414: ......
Страница 415: ......