6
Startup
DIP switches
Operating Instructions – MOVIGEAR
®
performance
130
6.3.2
Description of the DIP switches
DIP switch S1/1: Direction of rotation reversal (PROFINET, EtherNet/IP™, Modbus TCP)
INFORMATION
The direction of rotation is reversed depending on the setting of the DIP switch and of
the parameter drive train 1 > Controller >
Direction of rotation reversal
. If both set-
tings are active, the speed setpoint is not inverted (logical XOR).
You can reverse the direction of rotation of the drive using this DIP switch.
•
OFF (S1/1 = OFF): The drive turns CW for a positive setpoint and CCW for a neg-
ative setpoint.
•
ON (S1/1 = ON): The drive turns CCW for a positive setpoint and CW for a negat-
ive setpoint.
DIP switch S1/2: Disable holding function without enable (PROFINET, EtherNet/IP™, Modbus TCP)
WARNING
Risk from falling loads.
Severe or fatal injuries.
•
Do not activate the function "Disable holding function without enable" for hoist
applications and applications with potentially falling loads.
INFORMATION
For more information about disabling DynaStop
®
without drive enable, refer to the
chapter "Operation".
INFORMATION
If the function of this DIP switch is disabled via parameter access, the last active set-
ting is maintained.
Use this DIP switch to disable the holding function (DynaStop
®
) even if the drive is not
enabled.
•
OFF (S1/2 = OFF): You cannot deactivate the holding function without drive en-
able.
•
ON (S1/2 = ON): You can deactivate the holding function without drive enable. The
holding function is then controlled via digital input or process data bit.