7
Service
Status and error display
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
69
LED
Color
Status
Meaning
Operating state
Error code
Possible cause
Red
Flashing slowly
Fault 08
Speed monitoring error (only when S2/4 = "ON")
or additional function 13 is active.
Fault 09
Startup fault
Additional functions 4, 5, 12 (DIP switches S2/5 – S2/8) are
not permitted.
Firmware does not support MLK..A option
(only for MOVIMOT
®
with AS-Interface).
Fault 15
24 V supply error
Faults 17 – 24,
37
CPU error
Faults 25, 94
EEPROM error
Faults 38, 45
Unit/motor data error
Fault 44
The current limit was exceeded for more than 500 ms. (only
with additional function 2)
Fault 90
Incorrect motor/inverter assignment.
Fault 97
Error while transmitting a parameter set
Red
3x flashing, pause
Fault 01
Overcurrent in output stage
Fault 11
Overtemperature in output stage
Red
4x flashing, pause
Fault 84
Motor overload
Red
5x flashing, pause
Fault 4
Brake chopper fault
Fault 89
Brake overtemperature
Incorrect motor – frequency inverter assignment.
At terminals X1:13– X1:15, both brake and braking resistor are
connected. This is not permitted.
Red
6x flashing, pause
Fault 06
Line phase failure
Fault 81
Start condition
Fault 82
Output phases are interrupted.
Red
steady light
Not
ready
Check 24 V supply.
A smoothed DC voltage with a maximum residual ripple of
13% must be present.
Status LED flash codes
Flashing steadily:
LED 600 ms on, 600 ms off
Flashing steadily, fast:
LED 100 ms on, 300 ms off
Flashing with alternating colors:
LED 600 ms green, 600 ms yellow
Flashing with alternating colors, pause:
LED 100 ms green, 100 ms red, 100 ms green, 300 ms pause
N x flashing, pause:
LED N x (600 ms red, 300 ms off), then LED off for 1 s