6
Startup of MOVIMOT
®
with MLK.. in Easy mode
Description of the control elements
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
45
6.4.3
Switch t1
Use switch t1 to set the acceleration of the MOVIMOT
®
drive. The ramp time is based
on a setpoint step change of 1500 min
-1
(50 Hz).
3
4
5
6
7
8
Switch t1
Detent setting
0
1
2
3
4
5
6
7
8
9
10
Ramp time t1 s
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
27792307/EN – 07/2022