6
Startup of MOVIMOT
®
with MLK.. in Easy mode
Requirements
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
44
6.3
Requirements
The following conditions apply to startup:
•
The MOVIMOT
®
drive must be installed correctly both mechanically and electrical-
ly.
•
Appropriate safety measures prevent the drives from starting up unintentionally.
•
Appropriate safety measures must be taken to prevent risk of injury or damage to
the machine.
6.4
Description of the control elements
6.4.1
Setpoint potentiometer f1
NOTICE
Loss of warranted degree of protection if the screw plugs of the f1 setpoint potenti-
ometer or the X50 diagnostic interface are installed incorrectly or not at all.
Damage to the MOVIMOT
®
inverter.
•
After setting the setpoint, make sure the screw plug of the setpoint potentiometer
has a seal and screw it in.
Use the f1 potentiometer to adjust setpoint f1.
100
[1]
2
1
0
2 3 4 5 6 7 8 9 10
75
25
50
6
5
f1
f1
Hz
27021598093635979
[1]
Potentiometer setting
Setpoint f1 is active when the AS-Interface bit DO2 "speed f2/sped f1" = "0".
6.4.2
Switch f2
Use the f2 switch to adjust setpoint f2.
3
4
5
6
7
8
Switch f2
Detent position
0
1
2
3
4
5
6
7
8
9
10
Setpoint f2 [Hz]
5
7
10
15
20
25
35
50
60
70
100
Minimum frequency
[Hz]
2
5
7
10
12
15
20
25
30
35
40
Setpoint f2 is active when the AS-Interface bit DO2 "speed f2/speed f1" = "1".