TRANSMITTER - RECEIVER VERSION
Basic characteristics
Ÿ
Detector:
Project, Technology, Design and Production fully made in Italy
Ÿ
Suitable for use in all civil and industrial premises
Ÿ
Very easy to install and program
Ÿ
Low cost for mounting, cabling and maintenance
Ÿ
The Detector can be installed horizontally or vertically and can work at any angle
Ÿ
Micrometric adjustment for alignment
Ÿ
Integrated diaphragm with a wide range of adjustment
Ÿ
Control Unit
for programming, calibration and performing of remote test on line
beam detectors.
Ø
B a s i c c o n f i g u r a t i o n f o r t w o D e t e c t o r s e v e n o f d i ff e r e n t t y p e s
Transmitter/Receiver or Reflection
Ø
Expansion board for connection up to 3 to 8 detectors and line loop closure
(optional)
Ø
Ground level installation for the Control Unit
Ø
Alarm and Fault outputs can be programmed for each individual detector
Ø
Operational access to keyboard protected by password
Ø
Control Unit or Control Panel reset facility or by the MRS module
Ÿ
Base
Ø
Plug-in base to detector connection
Ø
Base complete with back up board short circuit isolator to ensure continued
work even after a short circuit
Ÿ
Special Allen Key
suitable for mechanical alignment, diaphragm regulation, unhook of
detector base and open/close of control unit
Product characteristics
Ÿ
Standard EN 54-12
Ÿ
Protection rating IP65 (Transmitter Unit, Receiver Unit and Controller Unit)
Ÿ
RoHS Compatibility
Ÿ
Operating distance 10 ÷ 200 m for Tx/Rx model
Ÿ
Width of cover up to 15 m
Ÿ
Connections to 4 serial line conductor RS485
Ÿ
Local and remote maintenance request
Ÿ
Automatic threshold compensation
Ÿ
Angle misalignment ± 1degree max
Ÿ
Complete directional stability over time
Ÿ
Sensitivity adjustable and selectable over a wide range, using the control unit model CSRLS
Ÿ
Automatic reset of detector after break in infrared beam
Ÿ
Self tester for RS485 communication
Ÿ
Fault relay output delayed up to 90 seconds
Ÿ
Power supply 24 V DC
Ÿ
It is available, on request, the Control unit model CSRLS in the DUST version, with special
thresholds applicable in critical environments characterised by high levels of dust, steam or
other vapours
ENGLISH
Mod. MII
rev. 01
SETRONIC Verona
51
Содержание ILIA ERHSO712
Страница 1: ......
Страница 3: ...ENGLISH MANUAL ...
Страница 4: ......
Страница 6: ...HIGH SENSITIVITY LINEAR BEAM DETECTOR MODEL ERHS0712 ENGLISH 50 Mod MII rev 01 SETRONIC Verona ...
Страница 15: ...HIGH SENSITIVITY REFLECTION SYSTEM DETECTOR MODEL ERRHS0712 ENGLISH Mod MII rev 01 SETRONIC Verona 59 ...
Страница 24: ...CONTROLLER FOR BEAM DETECTOR MODEL CSRLS MODEL CSRLS Dust 68 Mod MII rev 01 SETRONIC Verona ENGLISH ...