Modes of operation
Intelli-FLEX II product guide • • • 6 - 5
Monitor mode LED’s and display
The following section details the function of each LED that is available when the
Configuration module is in Monitor mode.
Monitor LED
Indicates the processor is operating in the monitor mode. In this mode, the
operator can monitor the detection activity for the indicated zone and threat
scenario.
Zone 1 LED
Indicates that the displayed value is relevant to parameters or status in zone 1.
Some parameters, apply to both zones. When this is the case, both zone 1 and
zone 2 LEDs will be lit.
Zone 2 LED
Indicates that the displayed value is relevant to parameters or status in Zone 2.
Cut LED
Indicates that the displayed value is relevant to a cut intrusion scenario. It refers
to inputs from the sensor cable which are typically classified as cut events. These
events are short duration, high amplitude, and occur with short delays between
events.
For example, when
Zone 1
and
Cut
are lit, the displayed value is the number of
cut events that remain before an alarm is initiated. This number will decrease
each time a cut event occurs.
The
Cut
LED will also illuminate along with the
Alarm
LED and appropriate
Zone
LED when a cut scenario from either zone triggers an intrusion alarm.
Climb LED
Indicates that the displayed value is relevant to a climb scenario. It refers to inputs
to the sensor cable which are typically classified as climb events. These events are
of a more continuous nature.
The
Climb
LED will also illuminate along with the
Alarm
LED and appropriate
Zone
LED when a cut scenario from either zone triggers an intrusion alarm.