![SENSTAR Intelli-FLEX II Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/senstar/intelli-flex-ii/intelli-flex-ii_product-manual_1244251079.webp)
Intelli-FLEX II processor settings
Intelli-FLEX II product guide • • • 5 - 43
The DC power/float charger modules can supply 12 VDC to the processor and
charge the 12 volt gel cell battery. The battery can be installed in the NEMA
enclosure with the processor, or at a location inside a building, directly to the DC
power/float charger.
The Model P0119 power supply/float charger (SSC P/N
IFLPS100-230) MUST have a battery connected across
its outputs.
To power the system from the DC power/float charger modules proceed as
follows:
•
Locate a source of AC power. It should be within 61 to 91 m (200 to 300 ft.)
from the processor, maximum, depending on the gauge of the power cable.
•
Make the following connections:
•
From the gel cell battery to the processor connect:
•
Black lead to TB1-3
•
Red lead to TB1-4
•
From the DC Power/Float Charger to the processor connect:
•
Black lead to TB1-3
•
Red lead to TB1-4
•
On the DC power/float charger connect:
•
Black lead to (—) and to earth ground
•
Red lead to (+)
•
Install the gel cell battery inside the NEMA enclosure.