glossary - 2 • • • Intelli-FLEX II product guide
Threshold
A level setting that an input signal from the sensor cable must exceed to be considered a cut or
climb event. These events are accumulated by the processor to determine alarm status.
Time window
A period of time that is initiated when a cut or climb event is first detected. During this time
window, cut and climb events are recorded. If the cut count or climb time requirement is
reached while the time window is still active, an alarm will occur. If the cut count or climb time
requirement is not reached, the time window will reset after a specified period of time. If
neither the cut count or climb time requirement is met before the time window resets, the cut
count and climb time accumulations are reset.