Basic sensor cable installation
5 - 4 • • • Intelli-FLEX II product guide
Drip loop
•
Install a drip loop at every cable connector. Form the drip loop by raising the
splice connector approximately 15 cm (6 in.) above the level of the cable run
before securing it, horizontally, to the fence fabric.
Ground contour
•
Secure the cable to the fence so that it follows the contour of the ground
while it maintains a constant distance from the ground (i.e., if the fence steps
up a hill, the cable should also step up the hill).
Figure 5-4 Adjacent zone overlap
Figure 5-5 Drip loop
terminator
zone 2
terminator
zone 1
sensor cable
sensor cable
zone 1
sensor cable
zone 2
intersection of 2 zones
with single cable run
intersection of 2 zones
with double cable run
end of zone overlap
1.5 m (5 ft.)
15 cm
(6 in.)
sensor cable
splice kit enclosure
drip loop