![SENSTAR Intelli-FLEX II Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/senstar/intelli-flex-ii/intelli-flex-ii_product-manual_1244251071.webp)
Cable devices
Intelli-FLEX II product guide • • • 5 - 35
The splice kit is used to join two cables together within a zone, either sensor
cable to sensor cable or sensor cable to non-sensitive feed cable. It is mounted
horizontally and attached to a fence post or fence fabric using two tie wraps.
The splice enclosure must remain dry during the
installation process. Always install the enclosure with a
horizontal orientation to protect the cable entry points
from rain and run off.
Materials
•
1 gel shell
•
1 terminal block
Installation instructions
1. Separate the shield and center conductor, twist the shield into a 'solid strand'.
Make sure that the screw terminals are open enough to accept wires.
2. Connect the sensor cable center conductor to one post of the terminal block.
3. Connect the shield to the adjacent post.
4. Connect the other sensor cable or non-sensitive feed cable center conductor
on the opposite post to the first center conductor connection.
5. Connect the shield to the remaining post.
6. Place the terminal block into the gel cavity of the shell.
7. Snap the two halves of the shell together.
8. Secure the completed assembly to the fence fabric horizontally at the top of
the drip loop, (see “Drip loop” on page 4), using two UV-resistant tie wraps.
Be sure to attach shield-to-shield, and center-to-center.
Caution