Standard components
3 - 2 • • • Intelli-FLEX II product guide
Standard components
Dual zone processor
Figure 3-2 Dual zone processor
The Intelli-FLEX II dual zone processor contains the circuitry necessary to
monitor one or two independent sensor zones. Generally, these two zones are
located beside each other. When used to monitor two zones, the Intelli-FLEX II
dual zone processor is capable of monitoring 610 meters (2,000 ft.) of sensor
cable, 305 meters (1,000 feet) per zone. For a single cable pass installation, with
service and corner loops included, this means that approximately 575 m (1885 ft.)
of fence can be monitored by one dual zone processor.
Non-sensitive feed cables are spliced together with the sensor cables and
connected to the processor at the F-connectors located at the top of the processor
card.
The terminal blocks along the bottom of the processor card contain connection
capacity for the processor power supply, alarm monitoring/reporting systems.
Corresponding LEDs indicate supervision and intrusion alarms for both zones 1
and 2, and system power on status.